Home
Scope of delivery
Safety
Required qualifications for installation work
Intended use
Technical data
Installation
Retrofitting RLS T2 WS
Replacing RLS T2 WS
Control elements, displays, functions
Standard display/start screen
Main menu value call-up
Operating mode selection
Ventilation level short code
System settings menu
Operating structure for system settings
Display
Time programme
System
Installer
Software version
Error memory
Information
Unit settings menu
Operating structure for unit settings
Basic settings
RLS 1 WR interlock
Room sensor configuration
Single control unit: RLS 1 WR control unit
Single control unit: Blocking OFF
Switching contact function
Bypass
Preheating register
Heat exchanger type
Acknowledgement of external safety device
Factory setting for control
Ventilation
Unit ventilation mode
Volumetric flow measurement (nominal ventilation)
Volumetric flow of ventilation level
EA/SA (exhaust air/supply air) adjustment
Night-time cooling / flush mode
Amount of air for volumetric flow compensation (Eco supply air)
Unit filter
External filter
Room filter
Duration of ventilation level
Motion detector overrun time
Ventilation time programmes
Regular time programme/holiday time programme
Time programmes cooling and heating function (releases)
Temperature settings
Room temperature adjustment
T supply air min. cooling
Maximum room temperature
Room setpoint temperature
Efficiency temperature settings min/max
Sensor settings
Combi sensor operation
Combi sensor humidity adjustment / Combi sensor temperature adjustment
Configuration of sensor 1 / sensor 2
Configuration of sensor 3 / sensor 4
CO2-/VOC-/Rel. Humidity limit value min./max.
CO2 value / VOC value / Rel. humidity Control voltage 0 V/10 V
Fireplace (ZP)
Brine earth heat exchanger (ZP 1, HP switching contact)
Zone ventilation (ZP1)
3-way air shutter (ZP 1)
Supplementary heating (ZP 1, HP switching contact)
Pressure consistency (ZP 2)
Filter monitoring (ZP 2)
EnOcean wireless (E-SM plug-in module)
KNX (plug-in module K-SM)
BACnet
Switching test
Internet
Main menu value call-up
Operating structure for call-up
Ventilation
Temperatures
Sensors
Switching statuses (outputs)
Operating hours
Internet
EnOcean wireless
Fault messages
Information
Special functions
Auto Sensor operation
Bypass
Frost protection strategies
Ventilation units with preheating register
Ventilation units without preheating register
Switching contact (potential-free)
Contact for external safety device
Switching test
Connection via network/web server
Operation via app
Factory settings
Functions of additional circuit boards
Additional circuit boards 1 (ZP 1)
Brine earth heat exchanger control
Zone ventilation
Air earth heat exchanger 3-way air shutter
Supplementary heating control
Additional circuit boards 2 (ZP 2)
EnOcean/KNX plug-in modules
Dismantling
Environmentally responsible disposal
Acknowledgements